🔧 Working Principle
The unit typically uses a triplex or quintuplex plunger pump driven by a diesel engine or electric motor. Cement slurry is prepared in the mixing system and then pumped at high pressure and controlled rate into the wellbore for casing cementing, plugging, or stimulation treatments. The entire system is mounted on a skid for easy lifting, transport, and installation.
📊 Key Components
Plunger Pump: Triplex or quintuplex, rated up to 10,000–15,000 psi.
Power Pack: Diesel engine or electric motor, typically 300–600 HP.
Transmission: Mechanical or hydraulic drive.
Mixing System: Recirculating mixer or jet mixer for cement slurry preparation.
Control Panel: Manual or PLC-controlled, with pressure and flow monitoring.
Skid Base: Heavy-duty steel skid with lifting lugs and tie-down points.
Auxiliary Equipment: Water tank, chemical additive system, manifold, and safety valves.
📏 Key Performance Parameters
Maximum Pressure: 10,000–15,000 psi (69–103 MPa).
Flow Rate: 0.5–3 m³/min depending on plunger size and speed.
Engine Power: 300–600 HP.
Plunger Diameter: 3"–4.5".
Skid Dimensions: Typically 6–12 m long, 2.5–3 m wide.
Weight: 15–30 tons depending on configuration.
📐 Common Standards
API Spec 7K: Drilling and well servicing equipment.
API Spec 10D: Casing centralizers and cementing accessories.
API RP 10B: Recommended practice for cementing.
ISO 9001: Quality management for manufacturers.
ATEX / IECEx: Required for offshore or hazardous-area installations.
💡 Selection Guidelines
For offshore platforms: Skid-mounted is preferred due to limited space and lifting requirements.
For fixed land well sites: Skid-mounted offers good stability and lower cost than trailer-mounted.
For high-pressure cementing: Choose a quintuplex pump rated at 15,000 psi.
For frequent relocation: Skid-mounted units require a crane or truck for transport; consider trailer-mounted if mobility is a priority.
Automation: PLC-controlled units provide better precision for complex cementing jobs.