🔧 Working Principle
The unit typically uses a triplex or quintuplex plunger pump driven by a diesel engine through a transmission. Cement slurry is prepared in the mixing system and then pumped at high pressure and controlled rate into the wellbore for casing cementing, plugging, or stimulation treatments. The truck chassis provides mobility, allowing the entire unit to drive directly to the well site.
📊 Key Components
Plunger Pump: Triplex or quintuplex, rated up to 10,000–15,000 psi.
Power Pack: Diesel engine, typically 400–600 HP.
Transmission: Mechanical or hydraulic drive, often with a torque converter.
Mixing System: Recirculating mixer or jet mixer for cement slurry preparation.
Control Panel: Manual or PLC-controlled, with pressure and flow monitoring.
Truck Chassis: Heavy-duty, road-legal chassis with driving cab.
Auxiliary Equipment: Water tank, chemical additive system, manifold, and safety valves.
📏 Key Performance Parameters
Maximum Pressure: 10,000–15,000 psi (69–103 MPa).
Flow Rate: 0.5–3 m³/min depending on plunger size and speed.
Engine Power: 400–600 HP.
Plunger Diameter: 3"–4.5".
Truck Chassis: Typically 6×4 or 8×4 configuration.
Gross Vehicle Weight: 25–40 tons depending on configuration.
Road Speed: Up to 60–80 km/h.
📐 Common Standards
API Spec 7K: Drilling and well servicing equipment.
API Spec 10D: Casing centralizers and cementing accessories.
API RP 10B: Recommended practice for cementing.
DOT / Road Regulations: For truck roadworthiness and transport.
ISO 9001: Quality management for manufacturers.
💡 Selection Guidelines
For scattered land well sites: Truck-mounted offers the best mobility and fastest relocation.
For high-pressure cementing: Choose a quintuplex pump rated at 15,000 psi.
For offshore or platform use: Skid-mounted is preferred due to space and lifting constraints.
For long-term fixed sites: Skid-mounted or trailer-mounted may be more economical.
Automation: PLC-controlled units provide better precision for complex cementing jobs.